      簡(jiǎn)單介紹
      JYM-303 meter, developed by our company, is a standard electric energy meter with characteristics of wide-range, multifunction and high-precision. It has accuracy grade of 0.02. By adopting techniques of DSP, embedded system and automatic temperature balancing and other compensation
      產(chǎn)品描述


      本產(chǎn)品由上海徐吉電氣有限公司精心推薦:


      產(chǎn)品特性:

      1. With cases of luxury sectional bar, A-series has a luxurious appearance. While with aluminum cases, B-series is portable, more smaller (it is the smallest one in domestic products of this kind. 355*145*185mm) , more lighter and easier to take.
      2. Wide-range measuring:
      Voltage measuring range (phase voltage):1~560V
         Current measuring range:                        10mA~120A
      3. Measurement of various ways: It has ability to measure AC voltage , current , power (active power, reactive power, apparent power) and electric energy in four-quadrant with connection modes such as single-phase and four-wire three-phase Y/ three-wire Δ. In addition, it can measure reactive power and electric energy with ways of true reactive, cross-phase reactive power, artificial neutral point of reactive.
      4. Multifunctional measurement:
      a. Fundamental function of measuring for voltage, current, phase, frequency, active power, reactive power, power factor and error.
      b. Measuring degree of stability of voltage, current and power.
      c.Measuring degree of asymmetry of voltage and current amplitude in three-phase circuits.
      d.Measuring degree of unbalancedness of voltage and current in three-phase circuits.
      e.Measuring degree of asymmetry of the phase.
      f.Display of vector diagram. There are a variety of display ways for vector diagram to meet the different display habits (such as clockwise rotation, counterclockwise rotation; the choice of the benchmark location between 12:00 o’clock and 3:00 o’clock; reference benchmark can be changeable; phase settings for display ways: 0~360°or ±180°).
      g.Waveform display, harmonic analysis, distortion calculation. Display of frequency spectrum, it can display the amplitude, contents and phase of the harmonic. Frequency spectrum can be enlarged.
      h.Dem measurement.
      i.Measurement of space magnetic induction intensity.
      j.Measurements of voltage drop of the device’s dotted terminal.
      k.Measurement of the constant and frequency of the meter to be adjusted.
      l.Measurement of power of fundamental wave.
      m. It can adjust errors of three different kinds of meters (active power, reactive power, apparent power, voltage, and current).
      n.There are three ports for pulses to output. And its constants can be set automatically or manually. Types of constants can be set also: active power, reactive power, apparent power, voltage, and current.
      o. It can check the comprehensive error of device composed of three single-phase meters.
      p. It can be used as three single-phase standard meters.
      5. Measurement of power for fundamental wave: not only could it measure the full power (including powers of fundamental wave and orders harmonics), but also the fundamental power only.
      6. Adjustment of electric energy error: it can adjust the estimate value of standard deviation and computation error of electric energy meters as well as calibration device for energy meter. Moreover, counts of pulse and constants of meters to be checked can be set automatically so as to work effectively. Especially for the multi-constant standard meter and the energy meter calibration device, it will be more convenient. By adopting the use of special compensation techniques, error-beating would not be large because of the small load (the low frequency of the energy pulses). It can display the current error, the value of the standard deviation estimate and the average error.
      7.  Harmonic analysis: it can analyze the harmonics of voltage and current under 51 orders.
      8. Display of data and graphics: it can display the measuring working condition and multiple measuring data directly. It can also display the waveform of the voltage and current to be measured, the phase vector graph of the voltage and current and waveform of harmonic analysis directly.
      9. The measuring range can be switched manually or automatically.
      10. With storage function, it can store 30 groups of data records which can be searched and browsed according to the condition.
      11. With the function of Pinyin input method: Chinese Character, alphabet and symbol can be inputted.
      12. Connection: the input port of the wide-range current is a public port, and there is no need to change connection mode while the current is changed, so it is very convenient to use.
      13. Multi-use: it can be used as a standard-meter, also as a calibration device for energy meter. It can be used alone, with PC by remote communication, also with calibration device.
      14. Multiple ports for communication: RS485, RS232, USB, and baud rate can be set when using asynchronous communication.
      15. With 6.4(or 5.7)-inch 640*480 pixel TFT display, it shows clearly and colorfully.
      16. Operation: human orient design, reasonable combination of the function and simple operating.


      產(chǎn)品參數(shù):

      1. Current measurement (Actual valid value RMS)
      Range:0.2A、1A、5A、20A、100A, range switch automatically
      Display range:0.00000mA~120.000A
      Measurement error:distorted wave:±0.02%RD(10mA~120A)
       Fundamental:±0.02%RD(10mA~120A)
       2~21 harmonic:±0.1%RD(10mA~120A)
      Measurement time base:1s~99s
      2.  Voltage measurement (Actual valid value RMS)
      Range:60V、120V、240V、480V  range switch automatically
      Display range:0.00000V~576.000V
      Measurement error:
      distorted wave:±0.02%RD(40V~576V)
       Fundamental:±0.02%RD(40V~576V)
      2~21 harmonic:±0.1%RD(40V~576V)
      Measurement time base:1s~99s
      3.  Power measurement
      Measurement error:
      Distorted wave active power:±0.02% RD(40V~576V,10mA~120A,PF≥0.5)
      Sine wave reactive power:±0.02% RD(40V~576V,10mA~120A,PF≥0.5)
      Sine wave apparent power:±0.02% RD(40V~576V,10mA~120A,PF≥0.5)
      Fundamental active power:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      2-21 harmonic active power:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Display range:6 digital display
      4. Phase measurement(phase difference between each phase voltage and current)
      Measurement error:±0.01°(40V~576V,10mA~120A)
      Display range:0.000°~359.999°
      5.Power factor measurement(each phase power factor and three phase power factor)
      Measurement error:±0.0002(40V~576V,10mA~120A)
      Display error:-1.00000 ~ 0 ~ +1.00000
      6.Frequency measurement
      Measurement range:45~70Hz;
      Measurement error :±0.005%RD
      Display error:44.9999Hz ~ 69.9990Hz
      7.Harmonic content measurement
      Harmonic times:2…51 ( fundamental wave as 50Hz)
      Harmonic measurement error :±10%RD±0.1%(Rd as harmonic content reading)
      Distortion Measurement error :±10%RD±0.1%(Rd as distortion reading)
      8. Energy measurement
      Measurement error:
      Distorted wave active energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Sine reactive energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Sine active energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      Fundamental wave active energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
      2-21 harmonic active energy:±0.1%(40V~576V,10mA~120A,PF≥0.5)
      Display error:(0.00…999999)Wh、varh、VAh
      9. Energy error measurement
      Tested meter constant range:1~999999999999imp/kWh(kvarh、kVAh)
      Pulse no. set range:1~9999999
      10. Tested energy pulse input
      Pulse electric level:5…12V
       input Frequency:2MHz (max)
      Min. pulse width:250ns
      Min. pulse interval:250ns
      11. Standard energy pulse output
      Pulse electric level:5V±5%,100mA
      Output frequency:Rated frequency60kHz (while voltage、current limit, power factor as 1)
      Max. frequency: 72kHz(While voltage limit、1.2 current limit,power factor as 1)
      12.Standard deviation evaluated value
      Voltage, current , active/reactive power, active/reactive energy                       standard deviation evaluated value≤0.002%
      13.Variation caused by influence quantity
      Measurement circuit voltage influence:≤0.004%(Power supply variation ±10%)
      Measurement circuit frequency influence:≤0.004%(Power supply variation ±10%)
      Auxiliary power supply voltage influence:≤0.002%(Power supply variation ±10%)
      Auxiliary power supply frequency influence:≤0.002%(Power supply variation±5%)
      Auxiliary power supply phase influence:≤0.002%
      Reverse phase influence:≤0.002%
      Current 3 times harmonic influence:≤0.004%
      AC external magnificent influence(1m,400 turns):≤0.01%
      14. Temperature
      Temperature coefficient:≤0.0005% /℃
      Self-heat influence:≤0.01%
      Pre-heat time:≤30min
      15.24h deviation:≤0.004%
      16. Insulation resistance:
      The insulation between voltage、current  input terminal and meter cover、power supply terminal and meter cover should not less than 100MΩ
      Industrial frequency withstand voltage:
      Between voltage、current input  terminal & power supply terminal and meter cover should withstand 50Hz sine wave 2kV  1min test;Between voltage circuit and current circuit; difference phase of current circuit should withstand 600V test.
      17. Ambient
      Rated temperature:23℃±2℃
      Work temperature range:10℃~30℃
      Max. work temperature range:0℃~40℃
      Storage and transportation max. temperature range:-20℃~55℃
      Relative humidity:≤85%
      18. Others
      Auxiliary power supply: 220V±15%,50Hz±10%
      Power consumption: ≤30VA 
      Cabinet: 355 × 185 × 145 mm。
                              i.              Weigh: 7.5kg

      產(chǎn)品留言
      標(biāo)題
      內(nèi)容
      聯(lián)系人
      聯(lián)系電話
      電子郵件
      公司名稱
      聯(lián)系地址
      驗(yàn)證碼
      點(diǎn)擊換一張
      注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
      2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!
      主站蜘蛛池模板: 亚洲人成网站免费播放| 国产无遮挡猛进猛出免费软件| 午夜国产理论大片高清| 精品久久久久久无码人妻蜜桃| 欧美日韩国产亚洲沙发| 综合色久七七综合尤物| 久久久久久人妻无码| 国产精品二区中文字幕| 97亚洲色欲色欲综合网| 亚洲一级片一区二区三区| 人妻中文字幕精品一页| 亚洲国产av区一区二| 日韩伦理片| 天天爽夜夜爱| 国产精品久久久久久久久软件| 免费VA国产高清大片在线| 又黄又硬又湿又刺激视频免费| 在线观看无码av免费不卡网站 | 国产免费AV片在线看| 成av人电影在线观看| 国产永久免费高清在线观看| 色系免费一区二区三区| 18禁无遮挡啪啪无码网站破解版| 国产一区二区三区色成人| 欧美牲交a欧美牲交aⅴ图片| 亚洲精品av无码喷奶水网站| 中文字幕国产在线精品| 日韩欧美亚洲一区二区综合| 亚洲精品揄拍自拍首页一| 狠狠色狠狠综合久久| 亚洲中文字幕一二区日韩| 免费无码高H视频在线观看| 国产91色在线精品三级| 亚洲免费视频一区二区三区| 免费人成年激情视频在线观看| 国产18禁黄网站禁片免费视频| 任我爽精品视频在线播放| 国产高清不卡视频| 国产亚洲精品在av| 特黄三级又爽又粗又大| 一级做a爰片在线播放|